Mini Split Calculator

Calculate what size ductless mini split head a room needs in BTU from its area, climate, sun, insulation and occupants, with sizing for winter heating and multi-zone use.

By CalcBuilt Editorial TeamUpdated September 9, 2026Formulas checked against manufacturer specs, see how we calculate.

Quick answer: To size a mini split, multiply the room area by 20 to 35 BTU per square foot for your climate, then adjust for sun, insulation, ceiling height, occupants and a kitchen. A 20 x 15 ft room with 8 ft ceilings in a moderate climate needs 7,500 BTU per hour of cooling, so a 9,000 BTU head, or a 12,000 BTU head if it will also be the main heat source through a cold winter.
Your measurements
LengthWidth
Plan view from above: area is length times width.
Results update as you type. The link in your address bar saves these entries.

Results

Cooling load
7,500 BTU per hour
25 BTU per sq ft plus adjustments for 300 sq ft
Recommended head size
9,000 BTU
Smallest standard indoor head that meets the load (0.75 tons); heads come in 9k, 12k, 18k, 24k, 30k and 36k
Head size if it also heats
12,000 BTU
Sized for 9,375 BTU per hour, 25% above the cooling load. Heat pump output drops as it gets colder outside; oversize 20 to 30% for heating below 20 F, or choose a cold-climate model rated at 5 F
Room area
300 sq ft
8 ft ceiling
Multi-zone outdoor unit
Add each room's head size
Run the calculator for every room and total the heads. Outdoor units are sold from about 18,000 to 48,000 BTU for 2 to 5 heads, and most makers let the heads total up to about 130% of the outdoor rating since rooms rarely peak together
Planning estimate only
Manual J sizing governs
A licensed HVAC contractor's load calculation and the manufacturer's capacity tables at your design temperatures decide the final head and outdoor unit sizes

Mini Split formula

Base load = Area (sq ft) x BTU per sq ft  (20 mild, 25 moderate, 30 hot, 35 very hot)
Adjusted load = Base load x sun factor x insulation factor x Ceiling height / 8
Cooling BTU = Adjusted load + 600 x (people - 2) + 4,000 if kitchen
Head size = next standard head at or above the load (9k, 12k, 18k, 24k, 30k, 36k); for heating, size to 1.25 x Cooling BTU

Worked example

A 24 x 16 ft family room with 10 ft ceilings in a hot climate, very sunny, poorly insulated, with 4 people and an open kitchen: 24 x 16 = 384 sq ft. 384 x 30 = 11,520 BTU. Times 1.1 for sun, 1.15 for insulation and 10 / 8 for the ceiling: 11,520 x 1.1 x 1.15 x 1.25 = 18,216 BTU. Add 2 x 600 = 1,200 for the extra people and 4,000 for the kitchen: 23,416 BTU per hour.

The smallest head that covers it is 24,000 BTU, a 2 ton unit. If the same head will heat the room on 15 F nights, size for 23,416 x 1.25 = 29,270 BTU and pick a 30,000 BTU head, or pair a 24,000 BTU head with a cold-climate outdoor unit that holds its rated output at 5 F.

Quick reference

Largest room each head size can cool (8 ft ceiling, average sun and insulation, 2 people)
Head sizeTonsMild, 20 BTU per sq ftModerate, 25 BTU per sq ftHot, 30 BTU per sq ft
9,000 BTU0.75450 sq ft360 sq ft300 sq ft
12,000 BTU1600 sq ft480 sq ft400 sq ft
18,000 BTU1.5900 sq ft720 sq ft600 sq ft
24,000 BTU21,200 sq ft960 sq ft800 sq ft
30,000 BTU2.51,500 sq ft1,200 sq ft1,000 sq ft
36,000 BTU31,800 sq ft1,440 sq ft1,200 sq ft

Sizing a ductless head

A mini split head serves one room or one open area, so size it to that space alone: area times a climate factor, adjusted for sun, insulation, ceiling height, people and cooking. Then step up to the next standard head. Do not skip two sizes. An inverter compressor can throttle down, but a 24,000 BTU head in a bedroom that needs 6,000 will still cycle, run humid and cost more than a 9,000 BTU head.

If the head will be the main heat source, size it for heating instead. A heat pump's rated capacity is measured at 47 F outdoors and falls as the temperature drops, so for winters that regularly go below 20 F pick a head 20 to 30 percent above the cooling load, or choose a cold-climate model whose published capacity at 5 F still meets the room's heat loss. Check the manufacturer's capacity table, not just the nameplate.

Multi-zone systems

For more than one room, run the calculator for each and add the head sizes. Outdoor units are rated in total BTU for 2, 3, 4 or 5 heads, and the manufacturer publishes which head combinations each one supports. Because all rooms rarely peak at once, most brands allow the heads to total up to about 130 percent of the outdoor unit's rating, but going that high leaves no reserve for heating.

Every zone needs a line set run and a condensate drain, and most brands limit total line length and the rise between heads and the outdoor unit. A single-zone unit per room is often cheaper to run and more reliable than one large multi-zone unit, because each compressor matches its own load. Have a licensed HVAC technician pull the vacuum, charge the lines and wire the disconnect; the sizing here is a planning estimate.

Key facts

  • Ductless indoor heads come in 9,000, 12,000, 18,000, 24,000, 30,000 and 36,000 BTU; one ton of cooling is 12,000 BTU per hour.
  • Multi-zone outdoor units run 2 to 5 heads, occasionally 8, and are rated from about 18,000 to 48,000 BTU; the connected heads can usually exceed the outdoor rating by 30% or so.
  • Energy Star's cold-climate heat pump specification requires at least 70% of rated heating capacity at 5 F, and many models are listed to operate down to -13 F or lower.
  • A standard heat pump loses a large share of its heating capacity between 20 F and 0 F, which is why a head that is fine for summer can fall short in a northern winter.
  • Inverter mini splits modulate down to about 25 to 30% of rated capacity, so a slightly oversized head still runs long, quiet cycles instead of short-cycling like a window unit.

Frequently asked questions

What size mini split do I need for a 300 sq ft room?

About 7,500 BTU per hour in a moderate climate, so a 9,000 BTU head. In a hot, sunny room with poor insulation it rises to about 11,400 BTU, which calls for a 12,000 BTU head.

Should I size a mini split for cooling or heating?

For the larger of the two. If the heat pump is the main winter heat source, the heating load usually governs; size the head about 25% above the cooling load, or pick a cold-climate model rated at 5 F. For cooling-only rooms use the BTU calculator's figure and the next head size up.

Should I oversize a mini split for heating?

If the head is the primary heat and winters drop below 20 F, size it 20 to 30% above the cooling load, or pick a cold-climate model rated at 5 F. Otherwise size for cooling; an inverter head modulates down but cannot go below about a quarter of its rating.

Can one outdoor unit run several heads?

Yes. Multi-zone outdoor units serve 2 to 5 heads and are rated from about 18,000 to 48,000 BTU. Add the head sizes from each room to pick the outdoor unit, and confirm the combination is on the manufacturer's compatibility list.

Sources and references

Next steps for this project

  1. Insulation
  2. Blown-In Insulation
  3. Attic Ventilation
  4. Heat Loss
  5. BTU
  6. Furnace Size
  7. Mini Split

The usual order for a insulation & hvac project. See all insulation & hvac calculators.

Results are estimates based on standard formulas and typical product specifications. Confirm quantities with your supplier and local code before ordering.